  The cell assemblies have the CellTell? Positive Pressure Indicator on the top of the cell assembly to show that the cell is pressurized (Figure 3-10). This safety device indicates whether or not all pressure was reduced through the normal pressure bleeding procedure. If this indicator can be depressed and will stay depressed, there is no pressure in the cell. If it cannot be depressed, or will not stay depressed, the cell has pressure in it and it MUST NOT be disassembled. This device is installed in the top end of single-ended cells and in the top cap of double ended cells. A screen is not used with the top cap when the top cap has this safety device present.

  电池组件有CellTell?积极压力指示器的细胞组装表明细胞是加压(图3 - 10)。该安全装置指示是否所有压力都通过正常的压力出血程序降低。如果这个指标可以被抑制并将持续抑制,细胞内就没有压力。如果它不能被压抑,或将不会被压抑,细胞有压力,它不能被拆卸。该装置安装在单端单元的上端和双端单元的上盖上。当上盖上有此安全装置时,屏幕不与上盖一起使用。

  Certain tests may require that the test sample does not contact the pressurization medium. This requirement can be met by using a free floating piston. The free floating piston can be used with most cell combinations, both the 175 ml and the 500 ml sizes. These pistons are furnished with a suitable installation and removal tool. See Table 8-1 Accessories for part numbers and descriptions.During testing, sometimes the test fluid may solidify and plug the valve stems. Or the CellTell? Positive Pressure Indicator may become plugged, giving a false, no pressure reading. In these high risk situations, where pressure is trapped inside the cell, it is recommended to use the filter press cell clamp (Figure 3-11).

  某些测试可能要求测试样品不接触加压介质。这一要求可以通过使用自由浮动活塞来满足。自由浮动活塞可用于大多数细胞组合,无论是175毫升和500毫升的大小。这些活塞配有合适的安装和拆卸工具。零件编号及说明见表8-1附件。在测试过程中,有时测试流体会凝固并堵塞阀杆。或CellTell?积极压力指示器可能变得堵塞,给了一个错误,没有压力阅读。在这些高风险的情况下,压力被困在细胞内,建议使用压滤细胞钳(图3-11)。

  Fann has developed a bench top cell clamp to maintain force on the lid while the set screws are removed. Once the screws are removed, the lid can be allowed to slowly rise and release any trapped pressure in a controlled manner. The filter press cell clamp is available as a separate purchase.

  范恩已经开发了一种台式细胞夹,以保持压力的盖子,而固定螺丝是拆除。一旦拆卸螺丝,盖子就可以缓慢上升,并以可控的方式释放任何滞留的压力。滤压电池夹可单购买。

  The filter press can generally be arranged to suit the available space and the desires of the lab personnel, consistent with any established work processes. Some environments encourage a right-to-left flow, while others a left-to-right flow. Consideration should be given to the location where samples are prepared and the cells are cleaned following test completion. The type of pressurizing system may also dictate installation specific requirements, such as having a large compressed gas cylinder secured nearby. There should be sufficient storage area nearby for commonly used tools, as well as consumable, such as filter paper and pressurizing cartridges.

  压滤机一般可以根据实验室工作人员的需要和可用空间进行布置,符合任何既定的工作流程。一些环境鼓励从右到左的流,而另一些环境鼓励从左到右的流。在测试完成后,应考虑样品制备和细胞清洗的位置。加压系统的类型也可以规定安装的具体要求,例如在附近安装一个大型压缩气体钢瓶。附近应该有足够的储存空间存放常用工具,以及消耗品,如滤纸和加压筒。

  The heating jacket is equipped with a 115V or 230V power cord, approximately 5 ft (1.5 m) long. The heating jacket should be placed no farther than this distance from an available electrical outlet that has the correct voltage for the heating jacket. Because of the diversity in types of electrical outlets throughout the world, it may be necessary to replace the power cord’s plug.Ideally, the heating jacket should be placed to the left side of the electrical outlet, rather than directly in front or to the right of it. This reduces the risk of a thermal burn when unplugging the power cord from the outlet while the heating jacket is still hot.

  加热套配有115V或230V电源线,约5英尺(1.5米)长。加热夹套的放置距离不应超过与具有正确的加热夹套电压的可用电源插座的距离。由于世界各地的插座种类繁多,可能有必要更换电源线的插头。理想情况下,加热夹套应放置在电源插座的左侧,而不是直接放在前面或右边。这减少了在加热夹套仍然热的情况下从插座拔下电源线时发生热烧伤的风险。

  The power cord should be kept away from the noninsulated surface of the heating jacket while the jacket is in use and immediately afterwards. The area immediately above the heating jacket needs sufficient clearance for the fully assembled cell with valve stems to be placed into the heating jacket from above. Additional clearance should be considered if the cell handling tool is used to remove hot cells before they have cooled to room temperature. See Figure 5-1.The total overhead clearance from the surface supporting the heating jacket should be 25 陆 inches (65 cm), 28 inches (71 cm) with the cell handling tool, and 34 inches (86 cm) with the carbon dioxide pressurizing regulator installed.

  在加热夹套使用中及使用后立即将电源线远离加热夹套的非绝缘表面。紧靠加热夹套上方的区域需要足够的间隙,以便将带有阀杆的完整组装的电池从上方放置到加热夹套中。如果在热电池冷却到室温之前使用电池处理工具来移除热电池,则应考虑额外的间隙。见图5 - 1。净空高度从支持加热套的表面应该是陆25英寸(65厘米),28英寸(71厘米)的细胞处理工具,和34英寸(86厘米)与二氧化碳加压调节器安装。

  The type of pressurizing system may also dictate installation requirements, such as having a large compressed gas cylinder secured nearby. When an external pressurizing manifold is used, the compressed gas cylinder should be located within reach of the hoses that are attached to the pressure manifold, typically 3 feet (1 m). It is possible to extend these hoses to 6 feet (2 m) or more by purchasing additional hoses and proper fittings.The backpressure receiver attaches to the lower cell valve stem and sits directly beneath the heating jacket. No special installation considerations are indicated.

  加压系统的类型也可以规定安装要求,例如在附近安装一个大型压缩气体钢瓶。当使用外部密封箱,压缩气体钢瓶应位于触手可及的软管连接到集流管,通常3英尺(1米)。它可以扩展这些软管6英尺(2米)或更多通过购买额外的软管和适当的配件。反压力接收器连接到下单元阀杆上,并直接位于加热夹套下方。没有特别的安装注意事项。

  The filter press cell clamp is a safety tool that guards against the sudden release of the cell cap when the retaining screws are being removed, while pressure is trapped inside the cell. It should be in close proximity to both the heating jacket and the cell clean up area. If desired, it can be secured to the work surface through the holes provided, or otherwise clamped to prevent undesired movement.The filter press clamp is available for separate purchase.

  压滤盒夹是一种安全工具,当压滤盒内的压力被固定在固定螺丝上时,可防止压滤盒盖突然松开。它应该靠近加热夹套和电池清洁区域。如果需要,可以通过提供的孔将其固定在工作表面,或者用其他方式夹紧,以防止不需要的移动。压滤钳可单购买。

  Storage space near the cell preparation area should be provided for the hex wrench that is used to install, tighten and loosen the cell retaining screws. A small adjustable wrench that is used to tighten and loosen the valve stems needs to be kept near the heating jacket, especially when a test is being performed. Similarly, the cell handling tool should be kept near the heating jacket. The cell cap removal tool can be kept near the cell clean up area, or near the filter press cell clamp.

  应在电池准备区域附近为六角扳手提供存储空间,六角扳手用于安装、拧紧和松开电池固定螺丝。用于紧固和松开阀杆的小型可调扳手需要保持在加热夹套附近,特别是在进行测试时。同样,电池处理工具应保持在加热夹套附近。电池帽清除工具可以放在电池清理区域附近,也可以放在压滤电池夹附近。

  82839536 比重计 OFI 115-00

  83107124 加热套 Fann 206966

  82651450 500ml高温高压失水仪样品杯 Fann 209570

  82651457 175ml高温高压失水仪样品杯 Fann 209569

  83107123 175ml高温高压失水仪加热套 Fann 209506

  83107123 500ml高温高压失水仪加热套 Fann 209541

  81972339 滚子炉老化罐 OFI 175-50

  81490030 老化罐杯体内聚四氟O型圈 OFI 175-09-1

  81490030 老化罐杯体外部O型圈 OFI 175-46

  81972341 直径3/8英寸固定螺钉 OFI 175-14

  81972340 阀杆 OFI 175-16

  Consumables, such as filter paper and replacement O-rings, should be near the cell preparation area. The filter paper should be protected from exposure to water, grease, oils, and other fluids that could alter the filter characteristics.Before starting the test, the High-Pressure, High-Temperature Filter Press must be disassembled; the pressure source and backpressure assembly must be disconnected, and the filtration cell assembly must be removed from the heating jacket. Refer to Figures 3-1 and 3-2 when following these operating instructions.The test procedure is outlined in Tables 5-1 and 5-2 for drilling fluid and cement, respectively.美国Fann 206966 加热套杯式加热器流变仪原装供应

  耗材,如滤纸和更换o形环,应靠近电池制备区。滤纸应避免接触水、油脂、油和其他可能改变滤纸特性的液体。试验开始前,高压、高温压滤机拆卸;将压力源和反压力总成断开,并将过滤单元总成从加热夹套上拆卸下来。按照这些操作说明操作时请参阅图3-1和图3-2。钻井液和水泥的测试程序分别见表5-1和表5-2。美国Fann 206966 加热套杯式加热器流变仪原装供应

天厦(厦门)国际贸易有限公司提供杯式加热器流变仪原装供应美国Fann206966加热套,包括美国Fann,Fann 206966,加热套,杯式加热器流变仪的详细产品价格、产品图片等产品介绍信息。

小提示:杯式加热器流变仪原装供应美国Fann206966加热套为用户自行上传发布,其真实性、合法性由发布人负责。交易汇款需谨慎,请注意调查核实。

天厦(厦门)国际贸易有 5年

  • 泵阀,工业配件,传感器,消防探测系统
  • 海沧区海沧大道893号1507室

——— 认证资质 ———

  • 身份证
    个人认证已通过
  • 营业执照
    企业认证已通过
  • 微信
    微信认证已通过
  • 手机
    手机认证已通过
  • 邮箱
    邮箱认证已通过